Gocator 2300 & 2880 Series
Gocator Web Interface • Measurement • 138
5. Click in the ID field.
6. Enter a new ID number.
The value must be unique among all measurements.
7. Press the Tab or Enter key, or click outside the ID field.
The measurement IDwill be changed.
Common Measurement Settings
All tools provide region settings under the Parameter tab, and all measurements provide decision and
filter settings under the Output tab.
Many tools and measurements also have tool- and measurement-specific parameters. See the individual
measurement tools for details.
Source
For dual-sensor systems, you must specify a profile source for tools. The source determines which
sensor provides data for the measurement.
Depending on the layout you have selected, the Source drop-down will display one of the following (or a
combination). For more information on layouts, see Dual-Sensor System Layout on page 58.
Setting Description
Top Refers to the Main sensor in a standalone or dual-sensor system, the Main sensor in
Opposite layout, or the combined data from both Main and Buddy sensors.
Bottom Refers to a Buddy sensor in a dual-sensor system position in Opposite layout.
Top Left Refers to a Main sensor in Wide layout or to a Buddy sensor in Reverse layout in a
dual-sensor system position.
Top Right Refers to a Buddy sensor in Wide layout or to a Main sensor in Reverse layout in a
dual-sensor system position.
To select the source:
1. Go to the Scan page.
2. Choose Profile or Surface mode in the Scan Mode panel, depending on the type of measurement
whose decision you need to configure.
If one of these modes is not selected, tools will not be available in the Measure panel.
3. Go to the Measure page by clicking on the Measure icon.
4. In the Tools panel, click on a tool in the tool list.
5. Click on the Parameter tab in the tool configuration area.
6. Select the profile source in the Source drop-down list.