Gocator 2300 & 2880 Series
• 34
Network Setup
The following sections provide procedures for client PCand Gocator network setup.
Client Setup
Sensors are shipped with the following default network configuration:
Setting Default
DHCP Disabled
IP Address 192.168.1.10
Subnet Mask 255.255.255.0
Gateway 0.0.0.0
All Gocator sensors are configured to 192.168.1.10 as the default IP address. For a dual-sensor
system, the Main and Buddy sensors must be assigned unique addresses before they can be
used on the same network. Before proceeding, connect the Main and Buddy sensors one at a
time (to avoid an address conflict) and use the steps in See Running a Dual-Sensor System on
page 37 to assign each sensor a unique address.
To connect to a sensor for the first time:
1. Connect cables and apply power.
Sensor cabling is illustrated in
System Overview on page 18.