Gocator 2300 & 2880 Series
Protocols • Gocator Protocol • 308
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4101).
fileName[64] char 6 File name (null-terminated) of the job the sensor loads when it
powers up.
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4101).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
Reply
Get Loaded Job
The Get Loaded Job command returns the name and modified status of the currently loaded file.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4512).
Command
Field Type Offset Description
length 32u 0 Reply size including this field, in bytes.
id 16u 4 Reply identifier (0x4512).
status 32s 6
Reply status. For a list of status codes, see Commands on page
295.
fileName[64] char 10 Name of the currently loaded job.
changed 8u 74 Whether or not the currently loaded job has been changed (1: yes;
0: no).
Reply
Get Alignment Reference
The Get Alignment Reference command is used to get the sensor's alignment reference.
Field Type Offset Description
length 32u 0 Command size including this field, in bytes.
id 16u 4 Command identifier (0x4104).
Command

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2300 Series and is the answer not in the manual?

LMI Technologies Gocator 2300 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2300 Series
CategoryAccessories
LanguageEnglish

Related product manuals