Gocator 2300 & 2880 Series
Protocols • Modbus Protocol • 347
The measurement ID defines the register address of each pair. The register address of the first word can
be calculated as (1000 + 3 * ID). For example, a measurement with ID set to 4 can be read from registers
1012 (high word) and, 1013 (low word), and the decision at 1015.
In Profile mode, the measurement results are updated after each profile is processed.In Surface mode,
the measurement results are updated after each discrete part has been processed.
Register Address Name Type Description
1000 Measurement 0 High 32s Measurement value in µm (0x80000000
if invalid)
1001
Measurement 0 Low
1002 Decision 0 16u Measurement decision. Abit mask,
where:
Bit 0:
1 - Pass
0 - Fail
Bits 1-7:
0 - Measurement value OK
1 - Invalid value
2 - Invalid anchor
1003 Measurement 1 High
1004
Measurement 1 Low
1005 Decision 1
1006 Measurement 2 High
1007
Measurement 2 Low
1008 Decision 2
... ... ... ...
1057 Measurement 19 High
1058
Measurement 19 Low
1059 Decision 19
Measurement Register Map

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2300 Series and is the answer not in the manual?

LMI Technologies Gocator 2300 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2300 Series
CategoryAccessories
LanguageEnglish

Related product manuals