Gocator 2300 & 2880 Series
Troubleshooting • 383
l
Verify that the measurement target is within the sensor's field of view and measurement range. See Spe-
cifications on page 384 to review the measurement specifications for your sensor model.
l
Check that the exposure time is set to a reasonable level.See Exposure on page 84 for more information on
configuring exposure time.
Performance
The sensor CPU level is near 100%.
l
Consider reducing the speed. If you are using a time or encoder trigger source, see Triggers on page 75 for
information on reducing the speed. If you are using an external input or software trigger, consider reducing
the rate at which you apply triggers.
l
Consider reducing the laser profile resolution.
See Spacing on page 88 for more information on configuring resolution.
l
Review the measurements that you have programmed and eliminate any unnecessary measurements.