LED status Color Function
duration green - Weight values provided
- Load cell recognized
flashes alternately green/red Electronics are being configured.
4.6.5.2 Connection of Connexx modules
Connexx modules can be connected to the device via the options card PR 5510/05 (see
Chapter 4.6.4).
- ≤4 Connexx modules without external voltage supply
- >4 Connexx modules with external voltage supply (see Chapter 4.6.5.4)
When connecting the external voltage supply, the device automatically switches from
an internal to an external power supply.
- A maximum of 12 Connexx modules are possible.
- The connecting parts are listed in Chapter 4.6.5.3.
Cable lengths
Connecting part Recommended length
Between PR 5410 and Connexx module max. 40 m
Between PR 5410 and external voltage supply max. 3 m
Between the individual Connexx modules max. 10 m
Connections
Color abbreviations Color Description
wh white + Supply voltage
bu blue - Supply voltage
bn brown GNDC
gy
gr/ye
gray
green/yellow
CAN_L bus signal (material PUR)
CAN_L bus signal (material PVC)
bk black CAN_H bus signal
4 Device installation X3 Process Indicator PR 5410
Minebea Intec EN-73