11 Troubleshooting
11.1 Checking FX PLC Version Applicability (FX2N and FX2NC Series)
11. Troubleshooting
This chapter explains troubleshooting and error codes.
11.1 Checking FX PLC Version Applicability (FX2N and FX2NC Series)
Verify that the FX PLC main unit is an applicable version for inverter communication.
→ For version applicability, refer to Section 1.3.
11.2 Checking Communication Status Based on LED Indication
Check the status of the "RD(RXD)" and "SD(TXD)" indicator LEDs provided in the optional equipment.
11.3 Checking Installation
1. Mounting status
If the communication equipment is not securely connected to the PLC, communication is not possible.
→ For mounting method, refer to the respective communication equipment manual.
2. Power supply (for FX0N-485ADP)
The FX0N-485ADP requires a driving power supply. Verify that the power supply is provided correctly.
3. Wiring
Verify that the wiring to all communication equipment is correct. If the communication equipment is wired
incorrectly, communication is not possible.
→ For wiring method check, refer to Chapter 4.
LED status
Operation status
RD SD
Flashing Flashing Data is being sent or received.
Flashing Off Data is received, but is not sent.
Off Flashing Data is sent, but is not received
Off Off Data is not sent nor received.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U-232-BD and is the answer not in the manual?

Mitsubishi FX3U-232-BD Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U-232-BD
CategoryController
LanguageEnglish

Related product manuals