E-117
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
A
Common Items
B
N:N Network
C
Parallel Link
D
Computer Link
E
Inverter
Communication
F
Non-Protocol
Communication
(RS/RS2 Instruction)
G
Non-Protocol
Communication
(FX
2N
-232IF)
H
Programming
Communication
I
Remote
Maintenance
Apx.
Discontinued
models
Communi-
cation
functions
123
Waiting time
setting
123
Waiting time
setting
123
Waiting time
setting
123
Waiting time
setting
⎯⎯
124
CR and LF
presence/absence
selection
124
CR and LF
presence/absence
selection
124
CR and LF
presence/absence
selection
124
CR and LF
presence/absence
selection
PID
control
128
PID action
selection
128
PID action
selection
128
PID action
selection
128
PID action
selection
88
PID action
selection
129
PID proportional
band
129
PID proportional
band
129
PID proportional
band
129
PID proportional
band
89
PID proportional
band
130 PID integral time 130 PID integral time 130 PID integral time 130 PID integral time 90 PID integral time
131 Maximum 131 Maximum 131 Maximum 131 Maximum 91 PID maximum
132 Minimum 132 Minimum 132 Minimum 132 Minimum 92 PID minimum
133
PID action set
point for PU
operation
133
PID action set
point for PU
operation
133
PID action set
point for PU
operation
133
PID action set
point for PU
operation
93
PID action set
point for PU
operation
134
PID defferential
time
134
PID defferential
time
134
PID defferential
time
134
PID defferential
time
94
PID defferential
time
Commer-
cial power
supply-
inverter
switch-
over
⎯⎯
135
Commercial
power supply-
inverter switch-
over sequence
output terminal
selection
135
Commercial
power supply-
inverter switch-
over sequence
output terminal
selection
⎯⎯⎯⎯
136
MC switch-over
interlock time
136
MC switch-over
interlock time
137 Start waiting time 137 Start waiting time
138
Commercial
power supply-
inverter switch-
over selection at
alarm occurrence
138
Commercial
power supply-
inverter switch-
over selection at
alarm occurrence
139
Automatic
inverter-
commercial power
supply switch-
over frequency
139
Automatic
inverter-
commercial power
supply switch-
over frequency
Backlash
140
Backlash
acceleration
stopping speed
140
Backlash
acceleration
stopping
frequency
*2
140
Backlash
acceleration
stopping
frequency
*2
⎯⎯⎯⎯
141
Backlash
acceleration
stopping time
141
Backlash
acceleration
stopping time
*2
141
Backlash
acceleration
stopping time
*2
142
Backlash
deceleration
stopping speed
142
Backlash
deceleration
stopping
frequency
*2
142
Backlash
deceleration
stopping
frequency
*2
143
Backlash
deceleration
stopping time
143
Backlash
deceleration
stopping time
*2
143
Backlash
deceleration
stopping time
*2
Display
functions
144
Speed setting
switchover
144
Speed setting
switchover
144
Speed setting
switchover
⎯⎯⎯⎯
145
PU display
language
selection
145
PU display
language
selection
145
PU display
language
selection
145
PU display
language
selection
n13
(145)
PU display
language
FREQROL V500 Series FREQROL F500 Series FREQROL A500 Series FREQROL E500 Series FREQROL S500 Series
Function
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name