E-123
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
A
Common Items
B
N:N Network
C
Parallel Link
D
Computer Link
E
Inverter
Communication
F
Non-Protocol
Communication
(RS/RS2 Instruction)
G
Non-Protocol
Communication
(FX
2N
-232IF)
H
Programming
Communication
I
Remote
Maintenance
Apx.
Discontinued
models
Computer
link
function
(S500
Series
communi-
cation
parameter)
336
Communication
check time
interval
336
Communication
check time
interval
336
Communication
check time
interval
⎯⎯
n6
(336)
Communication
check time
interval
337
Waiting time
setting
337
Waiting time
setting
337
Waiting time
setting
n7
(337)
Wait time setting
338
Operation
command source
338
Operation
command write
338
Operation
command right
338
Operation
command source
n8
(338)
Operation
command write
339
Speed command
source
339
Speed command
write
339
Speed command
write
339
Speed command
source
n9
(339)
Speed command
write
340
Link startup mode
selection
340
Link startup mode
selection
340
Link startup mode
selection
340
Link startup mode
selection
n10
(340)
Link start mode
selection
341
CR and LF
presence/absence
selection
341
CR and LF yes/no
selection
341
CR and LF yes/no
selection
⎯⎯
n11
(341)
CR and LF
selection
342
EEPROM write
selection
342
EEPROM write
selection
342
EEPROM write
selection
342
EEPROM write
selection
n12
(342)
EEPROM write
selection
DeviceNet
communi-
cation
345
DeviceNet
address
(lower)
345
DeviceNet
address startup
data (lower byte)
345
DeviceNet
address startup
data (lower byte)
345
DeviceNet
address startup
data (lower byte)
⎯⎯
346
DeviceNet baud
rate (lower)
346
DeviceNet baud
rate startup data
(lower byte)
346
DeviceNet baud
rate startup data
(lower byte)
346
DeviceNet baud
rate startup data
(lower byte)
347
DeviceNet
address
(higher)
⎯⎯
347
DeviceNet
address startup
data (higher byte)
347
DeviceNet
address startup
data (higher byte)
348
DeviceNet baud
rate (higher)
348
DeviceNet baud
rate startup data
(higher byte)
348
DeviceNet baud
rate startup data
(higher byte)
Orientation
control/
encoder
feedback
control/
pulse train
input
350
Stop position
command
selection
⎯⎯
350
Stop position
command
selection
⎯⎯⎯⎯
351
Orientation
switchover speed
351
Orientation
switchover speed
⎯⎯
352 Creep speed
353
Creep switch
position
354
Position loop
switchover
position
355
DC injection start
position
356
Internal stop
position command
356
Internal stop
position command
357 In-position zone 357 In-position zone
⎯⎯ 358
Servo torque
selection
359
Orientation
encoder rotation
direction
359
Encoder rotation
direction
360
External position
command
selection
360
12-bit data
selection
361 Position shift 361 Position shift
362
Orientation
position loop gain
362 Position loop gain
⎯⎯ 363
Completion signal
output delay time
FREQROL V500 Series FREQROL F500 Series FREQROL A500 Series FREQROL E500 Series FREQROL S500 Series
Function
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name

Table of Contents