E-133
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
A
Common Items
B
N:N Network
C
Parallel Link
D
Computer Link
E
Inverter
Communication
F
Non-Protocol
Communication
(RS/RS2 Instruction)
G
Non-Protocol
Communication
(FX
2N
-232IF)
H
Programming
Communication
I
Remote
Maintenance
Apx.
Discontinued
models
The parameters No. 77 and No. 79 cannot be written in computer link operation using the FR-A5NR.
*1. Can be read or written when the parameter No. 77 is set to "801".
*2. Can be read or written when the parameter No. 29 is set to "3".
*3. Indicates a parameter whose setting is ignored when the advanced magnetic flux vector control mode
is selected.
*4. Can be set when the parameters Nos. 80 and 81 are not set to "9999" and the parameter No. 60 is set
to "7" or "8".
*5. Can be read or written when the parameters Nos. 80 and 81 are not set to "9999" and the parameter
No. 77 is set to "801".
*6. Can be set only in the 200 V/100 V class.
*7. Cannot be used in inverter communication.
Additional
functions
⎯⎯⎯⎯⎯⎯⎯⎯
n17
(993)
PU disconnection
detection/PU
setting lock
FREQROL V500 Series FREQROL F500 Series FREQROL A500 Series FREQROL E500 Series FREQROL S500 Series