¾ 5-15 ¾
Program 19
This program selects the functions for the system.
Display Indication Input Data Initial
SYS# ASSIGNMENT5
#####19###-ABCDE
A. All Call to External Zone
0: Disable 1: Speaker 1
2: Speaker 2 3: Speaker 1 and 2
(Can input 0 or 1 on TX-Z 308)
B. Intercom Call Type
0: Voice call 1: Signal call
C. Microphone ON/OFF (Initial condition)
0: ON 1: OFF
D. Room Monitor
0: Disable 1: Enable
E. Unanswer Transfer line
0: Cutoff
1:Transfer to No.10 Tel or operator extension
of each tenant.
(after pre-set timer(#29) is over.)
A: 1
B: 0
C: 0
D: 0
E: 0
Program 20
This program selects the functions for the system.
Display Indication Input Data Initial
SYS# ASSIGNMENT6
#####20###-ABCDE
A. Door Chime Tone Duration
0: 2 times 1: 30 seconds
B. Paging Splash Tone
0: Disable 1: Enable
C. Door Alert Tone
0: Disable 1: Enable
D. Automatic Trunk Access Code for SLT
0: Off-Hook and dial 0
1: Off-Hook and dial 9
E. Existence of Doorphone Box
0: None
1: Doorphone 1 enabled
2: Doorphone 2 enabled
3: Doorphone 1 and 2 enabled
A: 0
B: 1
C: 0
D: 1
E: 0