¾ 5-16 ¾
Program 21
This program sets the timer for Exclusive Hold Recall. The timer can be set in 10 second intervals,
up to 2550 seconds.
Display Indication Input Data Initial
EXC.HOLD# TIMERS#
#####21-N###-TTT
N. 1: Recall start time
2: Recall signal duration time
TTT. Time
000: Not assigned
001 - 255: 10 - 2550 seconds
(N = 1)
TTT: 003
(N = 2)
TTT = 003
Program 22
This program sets two timers for the System Hold feature:
1. The Recall Timer selects the interval of time a call stays on System Hold before it recalls (re-
rings) the extension that placed it on Hold. This timer can be set for 10 second intervals, up to
2550 seconds.
2. The Duration Timer determines how long the System Hold Recall signal lasts. The timer can be
set for a maximum of 255 seconds.
Display Indication Input Data Initial
SYS.HOLD# TIMERS#
#####22-N###-TTT
N. 1: Recall Timer
2: Duration Timer
TTT. Time
000: Not assigned
001 - 255: 10 - 2550 seconds (N = 1)
1 - 255 seconds (N = 2)
(N = 1)
TTT: 006
(N = 2)
TTT = 005
Program 23
This program determines how long an Unannounced Transfer rings the receiving extension before
recalling the transferring extension. The timer can be set for multiples of 10 seconds, up to 2550
seconds.
Display Indication Input Data Initial
UNANN.XFER# TIMER
#####23#####-TTT
TTT. Recall time
000 - 255: 0 - 2550 seconds
TTT: 006