¾ 5-17 ¾
Program 24
This program determines how long an Announced Transfer stays on System Hold before recalling
the transferring extension. The timer can be set in 10 second intervals, up to 2550 seconds.
Display Indication Input Data Initial
ANN'D# XFER# TIMER
#####24#####-TTT
TTT. Recall time
000: I-Hold transfer disabled
001 - 255: 10 - 2550 seconds
TTT: 000
Program 25
This program enables or disables the Call Duration Timer feature. If enabled, the Call Duration
Timer can be programmed to start from 1 to 255 seconds after a line is accessed.
Display Indication Input Data Initial
CALL# DUR.# START#
#####25#####-TTT
TTT. Start time
000: Not indicated
001 - 180: 1 - 180 seconds
TTT: 015
Program 26
This program sets the duration of the open loop flash used for the Flash feature. One duration is
available for Trunk lines and another for PBX lines. A flash duration can range from 30 to 7500 ms
(30 ms intervals).
Display Indication Input Data Initial
FLASH# TIMER#####
#####26-N###-TTT
N. Line type
1: CO Line 2: PBX Line
TTT. Flash time
000: Not assigned
001 - 250: 30 - 7500 ms (30 ms step)
(N = 1)
TTT: 025
(N = 2)
TTT: 003