¾ 5-18 ¾
Program 27
This program sets two SMDR timers:
1. Call Duration Timer selects the minimum number of seconds (00-60) a call must last in order for
it to be recorded on the SMDR printout.
2. Call Start Timer selects the number of seconds (00-60) which pass before SMDR starts timing a
call.
Display Indication Input Data Initial
SMDR# TIMERS#####
#####27####XX-TT
XX. 01: Minimum call duration timer
02: Inter-digit timer
(01 and 02 cannot input dial)
TT. Time
00: Not assigned
01 - 60: 1 - 60 seconds
(XX = 01)
TT: 00
(XX = 02)
TT: 10
Program 28
This program determines how long an extension rings before transferring a call to other extension
(Call Forward when Unanswered). The timer can be set from 1 to 255 seconds.
Display Indication Input Data Initial
DELAY# RING# TIMER
#####28#####-TTT
TTT. Time
000: Time out disabled
001 - 255: 1 - 255 seconds
TTT: 015
Program 29
This program determines Attendant Revert Timer. A call left on System Hold longer than a this
programmed period of time, re-rings the attendant telephone (station #10 or operator extension of
each tenant).
Display Indication Input Data Initial
ATT.REVERT# TIMER
#####29#####-TTT
TTT. Attendant revert timer assignment
000: Time out disabled
001 - 255: 1 - 255 seconds
TTT: 000