¾ 5-20 ¾
Program 32
This program determines release time of DTMF receiver for SLT.
Display Indication Input Data Initial
PB# REC.REL.TIMER
#####32#####-TTT
TTT. Time
000: Time out disabled
001 - 255: 1 - 255 seconds
TTT: 010
Program 33
This program determines interval time between Trunk line seizure and dialing when using Last
Number Dialing and Repeat Dialing.
Display Indication Input Data Initial
LINE# DROP# TIMER#
#####33#####-TTT
TTT. Time
000: Not cut off
001 - 010: 1 - 10 seconds
TTT: 003
Program 34
This program set following timers for the Automatic Repeat Dialing.
Display Indication Input Data Initial
REP.DIAL.TIMERS##
#####34-N###-TTT
N. Assigned items
1. Waiting time
2. Calling time
3. No. of times redialed
TTT. Time assignment or numbers
000 : No function
001 - 255: 1 - 255 sec
1 -255 times
(N = 1)
TTT: 180
(N = 2)
TTT:030
(N = 3)
TTT: 010