¾ 5-24 ¾
Program 44
This program selects normally open or normally closed contacts for each Alarm input.
Display Indication Input Data Initial
ALARM# SENSOR###
#####44-N###-A-B
N. Alarm number (1 - 2)
A. Alarm installed or not installed
0: Not installed 1: Installed
B. Alarm trigger condition
1) When internal power is used
0: Normally contacts 2: Normally open
2) When external power is used
0: Normally open 2: Normally contacts
(N =1 - 2)
A: 0
B: 0
Program 45
This program enables or disables the Intercom Link Increase feature.
Display Indication Input Data Initial
ICM# LINK# INCR.##
#####45######-DD
DD. Last line number used
00: Not assigned
01 - System Max minus 1:
Last line number used
* When this System Programming finished, this
system is reset.
DD: 00
Program 46
This program creates DISA Security Codes. Up to eight security codes can be created. The security
codes are identified by the numbers 1 - 8, and each code is four digits long.
Display Indication Input Data Initial
DISA# SEC.CODES##
#####46-N##-DDDD
N. Security Code number (1 - 8)
DDDD. Security Code
(From 1 to 4 digits long)
* To clear data, press OPAC key.
(N = 1 - 8)
DDDD :
No settin