PM TABLES 15 February 2006
2-4
FUSING UNIT AND PAPER EXIT
EM 300K 500K 600K Expected K Note
Cleaning Web R R
Cleaning Web Pressure
Roller
R
Cleaning Web Pressure
Roller Bearings
R
Replace roller and bushings
together.
De-Curler Rollers C C Alcohol
Exit Rollers C C Alcohol
Exit Static Discharge
Brush
I I
Fusing Entrance Guide
Plate
C C
Dry cloth.
Fusing Exit Guide Plate C C Dry cloth.
Hot Roller R R 600
Hot Roller Bearings
R R 1000
B140/B246 Series: “R” at
300K
B064 Series: “R” at 500K
Hot Roller Strippers R R 600
Pressure Cleaning Roller R R
Pressure Cleaning Roller
Bearings
R I R
Replace as a set.
Pressure Cleaning Roller
Spring Plate
I I
Pressure Roller R R 600
Pressure Roller Bearings
R R 600
B140/B246 Series: “R” at
300K
B064 Series: “R” at 500K
Always replace pressure
roller and bearings together.
Thermistors x2
R I
B140/B246 Series: “R” at
300K
B064 Series: “I” at 500K
Transport Rollers C C Alcohol
Fusing Lamp I I I
DUPLEX
EM 300K 450K 600K Expected K Note
Entrance Sensor C C C Blower brush
Inverter Exit Rollers C C Alcohol
Transport Rollers C C Dry cloth
Reverse Trigger Rollers C C Dry cloth
Inverter Entrance Roller C C Dry cloth
Entrance Anti-Static
Brush
C C
Blower brush
Reverse Junction Gate C C C Dry cloth