B140/B246 SERIES SERVICE MODE 15 February 2006
4-72
SC900: Miscellaneous
SC No. Symptom Possible Cause
Electrical total counter error
B140
900 D
The total counter contains
something that is not a number.
NVRAM incorrect type
NVRAM defective
NVRAM data scrambled
Unexpected error from external source
Mechanical total counter error 901 D
The mechanical counter is not
connected.
Mechanical total counter defective
Mechanical total counter connector not
connected
910 D
External Controller Error 1
911 D
External Controller Error 2
912 D
External Controller Error 3
913 D
External Controller Error 4
914 D
External Controller Error 5
B140/B246
The external controller alerted
the machine about an error.
Please refer to the instructions for the
external controller.
External Controller Error 6 B140/B246 919 B
While EAC (External Application
Converter), the conversion
module, was operating normally,
the receipt of a power line
interrupt signal from the FLUTE
serial driver was detected, or
BREAK signal from the other
station was detected.
Power outage at the EFI controller
EFI controller was rebooted
Connection to EFI controller loose
Printer error 1
B140
920 B
An internal application error was
detected and operation cannot
continue.
Software defective; turn the machine
off/on, or change the controller firmware
Insufficient memory
Printer error 2
B140
921 B
When the application started,
the necessary font was not on
the SD card.
Font not on the SC card