15 February 2006 PCBS AND HDD
3-137
Replacement
Adjustment
After Installing the New NVRAM
1. Connect the power cord and switch the machine on.
2. Enter the SP mode and execute SP5801 (Memory All Clear)
3. Execute SP5825 (NVRAM Download) to download the data uploaded onto the
SD card in SD card slot C3.
16. Switch the machine off and on.
17. Execute SP5990 to print another SMC report. Confirm that all the SP settings
have been initialized.
18. Execute SP3001-002 (ID Sensor Initialization) to initialize the ID sensor.
19. Execute SP5907 (Plug & Play) and enter the brand and model name of the
machine for Windows Plug & Play capability.
20. For details about SP initial settings, see “Section 5 Service Tables”.