B140/B246 SERIES SERVICE MODE 15 February 2006
4-52
Tandem rear fence motor error 515 B
One of the conditions is detected:
The return sensor does not
switch on within 10 sec. after the
rear fence motor switches on.
The HP sensor does not switch
on 10 sec. after the rear fence
motor switches on.
The HP sensor and return sensor
switch on at the same time.
Rear fence motor defective or poor
connection
Paper or other obstacle interfering with
operation of the sensors
Paper or other obstacle trapped between
tray and motor
Motor mechanical overload due to
obstruction
Return sensor or HP sensor defective or
dirty
Note (B246)
This problem will not issue the SC code
on the operation panel.
The machine will prompt the operator to
reset tray by opening and closing it.
If the problem persists, the machine will
display again and the tray cannot be
used.
Duplex jogger motor error 1 520 C
When the jogger fence moves to
the home position, the jogger HP
sensor does not turn on even if the
jogger fence motor has moved the
jogger fence 153.5 mm.
Paper or other obstacle has jammed
mechanism
Sensor connector disconnected or
defective
Sensor defective
Duplex jogger motor error 2 521 C
When the jogger fence moves from
the home position, the jogger fence
HP sensor does not turn off even if
the jogger motor has moved the
jogger fence 153.5 mm.
Paper or other obstacle has jammed
mechanism
Sensor connector disconnected or
defective
Sensor defective
Fusing exit motor error 531 D
The PLL lock signal was low for 2
seconds during motor operation.
Motor lock caused by physical overload
Motor drive PCB defective
Fusing thermistor open 541 A
The fusing temperature detected by
the center thermistor was below
0°C for 7 sec.
Thermistor open
Thermistor connector defective
Thermistor damaged, or out of position
Fusing temperature –15% less than the
standard input voltage
Fusing temperature warm-up error 542 A
One of the following occurred:
After power on, or after closing
the front door, the hot roller does
not reach the 100°C control
temperature within 25 s.
5 sec. after temperature rise
started, temperature remained
below 21°C after 5 samplings.
Fusing unit did not attain reload
temperature within 48 sec. of the
start of fusing temperature
control.
Fusing lamp disconnected
Thermistor warped, out of position
Thermostat not operating