15 February 2006 SERVICE PROGRAM MODE TABLES
5-43
Service
Tables
2906* TD Sensor Control Voltage and Check
001 TD Sensor Control Voltage Setting
Adjustment mode for production. DFU
[4.0~12.0/0.1]
002 Automatic Adjustment Setting
Displays the TD sensor data stored when SP2801 (TD Sensor Initial Settings) is
executed.
2909* Main Scan Magnification
001 Copy
Adjusts magnification in the main scan direction for copying.
[–2.0~+2.0/0.1%]
002 Printer
Adjusts magnification in the main scan direction for printing from a computer.
[–2.0~+2.0/0.1%]
2910* Sub Scan Magnification
Adjusts magnification in the main scan direction for copying.
[–1.0~+1.0/0.1%]
2912* Drum Reverse Rotation
001 Rotation Amount
Sets the length of time the drum is reversed to clean the drum cleaning blade.
[1~3/1]
To calculate the actual time of reverse rotation, multiply the selected value by the
15 ms.
002 Rotation Interval
Determines the frequency of drum reverse rotation for blade cleaning.
[0~6/1 min.]
2913* Temperature & Humidity Display
001 Machine Temperature Shows the internal temperature of the machine.
002 Machine Humidity Shows the internal humidity of the machine.
2920* LD Off Check
Checks if the LD turns off or on when the front door is opened. DFU
[0~1/1]
0: On
1: Off