SERVICE PROGRAM MODE TABLES 15 February 2006
5-52
2968 Toner Exit Mode
Press Execute to force used toner into the toner collection bottle. The moving
components of the cleaning and toner collection areas will rotate for about 60 sec.
with the transfer belt released.
2969* Toner Bottle Revolution Count
001 Copy Count Setting Sets the standard number of copies by using the
number of toner bottle rotations. DFU
[50~500/1]
002 Count Reset Press “Execute” to reset the toner bottle rotation count.
DFU
003 Copy Count Display 1 Used to check the number of toner bottle rotations.
2970* Transfer Belt Resistance: Disp. Current Value (B140)
Displays the resistance of the bare transfer belt at the interval between the leading
edge of a sheet and the trailing edge of the sheet ahead of it in the paper path.
The displayed value is (MΩ). DFU
2971* Trans. Interval Output
001 Voltage
002 Current
Displays the measurement condition of the value in
SP2970.
2972* Toner Bottle Cool. Fan Drive Control
Switches fan control On/Off.
[0~1/1]
0: Off. The toner bottle fan switches off when the machine is powered off and
when the machine enters the night mode.
1: On: Toner bottle fan remains on.
Switch on in an extremely hot environment to prevent the toner from overheating
and clumping.