15 February 2006 SERVICE PROGRAM MODE TABLES
5-61
Service
Tables
4610* White Level Adj: Next
4613* White Level Adj.: Previous Normal
4616* White Level Adj.: Factory
4624* Read Offset Data
4632* Gain Adjustment DFU
4641* White Adjust Loop
4646* SBU Adjustment Error Flag
4647* SBU Hard Error Flag
4662* Gain Adjustment Normally
4681* Gain Adjustment at Factory
4691* Read Shading Data
4694* Black Level
4700* Read CIS ASIC ID
Reads and displays the ID of the CIS board at power.
4701* Frequency Adjust DFU
4702* Periodic Adjustment Setting
4705 CIS Adjustment
001* Flag Display
Displays whether density adjustment was executed for the CIS, using the white
roller.
[0~1/1]
0: Not executed
1: Executed
002 Start
Starts the standard white density adjustment for the CIS. Place 5 sheets of A3 on
the exposure glass, then press Execute. A message is displayed to indicate the
success or failure of the adjustment. DFU
4713* CIS White Level Adjustment
4716* CIS White Level Adjustment
4732* CIS Gain Adjustment
4735* CIS Read White Level
4741* CIS White Adjust Loop
DFU
4742* CIS White Roller Adjust Loop
4745* CIS Adjustment Overflow Flag
4747* CIS Adjustment Time Out Flag
4762* CIS Gain Adjustment Normal
4765* CIS Adjustment Overflow Flag
4781* CIS Gain Adjustment at Factory