EasyManua.ls Logo

Ricoh MT-C1 - Page 560

Ricoh MT-C1
865 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15 February 2006 SERVICE PROGRAM MODE TABLES
5-87
Service
Tables
156 Dial Up User Name
Use this SP to set a user name for access to remote dial up. Follow these rules
when setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double
quotation marks (").
157 Dial Up Password
Use this SP to set a password for access to remote dial up. Follow these rules
when setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double
quotation marks (").
159 Remote Service: Carrier Send Level
This SP sets the level of the carrier signal for Cumin-M data transmissions.
[0~15/3/1]
160 Remote Service: AT command
This SP allows you to add an AT command to the initialization of the Cumin-M
modem. This SP sets the AT command for both initialization and wait time of
and outgoing call. It also includes the NULL instruction.
Default: 0, up to 8 characters allowed.
161 Local Phone Number
Use this SP to set the telephone number of the line where Cumin-M is
connected. This number is transmitted to and used by the Call Center to return
calls.
Limit: 24 numbers (numbers)
162 Connection Timing Adjustment: Incoming
When the Call Center calls out to a Cumin-M modem, it sends a repeating ID
tone (*#1#). This SP sets the line remains open to send these ID tones after the
number of the Cumin-M modem is dialed up and connected.
[0~24/1/1]
The actual amount of time is this setting x 2 sec. For example, if you set "2" the
line will remain open for 4 sec.
163 Access Point
This is the number of the dial-up access point for Cumin-M. If no setting is done
for this SP code, then a preset value (determined by the country selected) is
used.
Default: 0
Allowed: Up to 16 alphanumeric characters
164 Line Connecting
This SP sets the connection conditions for the customer. This setting dedicates
the line to Cumin-M only, or sets the line for sharing between Cumin-M and a
fax unit.
[0~1/0/1]
0: Line shared by Cumin-M/Fax
1: Line dedicated to Cumin-M only
Note:
If this setting is changed, the copier must be cycled off and on.
SP5816 187 determines whether the off-hook button can be used to interrupt
a Cumin-M transmission in progress to open the line for fax transaction.

Table of Contents