261
Resolution Setting range
305 dpi (1 dot = 0.083 mm (0.0033")) -45 to +45 dots
When you decrease the setting value, the stop position moves in the feed direction.
When you increase the setting value, the stop position moves opposite the feed direction.
Darkness Adjust
Fine tune the print darkness of the test print.
0 is the lightest and 99 is the darkest.
• You can change the units to dots, " (inches), or mm in the [System] > [Regional] >
[Unit] menu.
• The changes to the settings in this menu are linked and are changed with each of the
test print settings under the [Test Print] menu.
• The settings in [Pitch], [Offset], and [Darkness Adjust] are linked and are changed with
the settings in the [Printing] > [Advanced] > [Adjustments] menu.
[Paper Sensor]
Print the detection result of the media sensor level.
1. Check and set the items as listed on the [Paper Sensor] menu.
2.
Tap to start the test print. Tap to pause printing.
To stop the test print, pause printing, and then tap .
The setting items are as follows:
Label Width
Shows the necessary media width of the test print.
The necessary media width is 50.8 mm (2") for [Small].
Label Length
Set the length of one piece of the media used for the test print.
The setting range varies depending on the print resolution of the product.
The setting range is as follows:
Resolution Setting range
203 dpi (1 dot = 0.125 mm (0.0049")) 400 to 1,600 dots
305 dpi (1 dot = 0.083 mm (0.0033")) 600 to 2,400 dots