Error Message 1111 (Label Waste Prevention Error)
When there is an error with the product, the error message appears on the screen.
Tap the error number button to show the details screen.
Check the cause and countermeasure, and then take appropriate action.
 
To clear the error:
Open the top cover, load the media so the leading edge is aligned with the media discharge outlet, and
then close the top cover.
Cause and Countermeasure Reference
Cause (1)
The position in which the media is loaded is incorrect.
Countermeasure (1)
Load the media so the leading edge is aligned with the
media discharge outlet.
 
About the Label Waste
Prevention Function
Cause (2)
The media is not detected correctly.
Countermeasure (2)
Use [Auto-calibration] to adjust the media sensor level.
 
Auto-calibration
Contact your SATO technical support if the error cannot be resolved.