Vista Digital Mixing System
3-22 Parameters SW V3.3 Date printed: 28.04.04
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–10–20–30–40–50–60–70–80–90 0
Input level
[dBFS]
Output level
[dBFS]
1
2
4
3
3.4.2 Dynamics Parameters
Limiter Parameters:
LIM On/Off [36] Limiter on/off.
LIM THRS [37] The limiter threshold can be adjusted in 1 dB steps from 0 dB
FS
to
–48 dB
FS
. The limiter threshold corresponds to the output level.
LIM REL [38] The limiter release time can be adjusted in 13 steps within a 10 ms to 10 s
range (10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms, 300 ms, 500 ms, 1 s,
2 s, 3 s, 5 s, and 10 s).
LIM hold on/off [39] Hold on = 150 ms, off = 0 ms.
LIM ATCK [40] The limiter attack time can be adjusted in 9 steps within a 200 µs to 1 ms
range (0.2 ms, 0.3 ms, 0.4 ms, 0.5 ms, 0.6 ms, 0.7 ms, 0.8 ms, 0.9 ms, and
1 ms).
Curve Limiter Threshold [dB]
1
OFF Any
1
ON 0
2
ON –20
3
ON –30
4
ON –40
[64]
[65]
[62]
[63]
[66]
[63]
[62]
[38]
[43]
[49]
[55]
[58]
[36]
[41]
[42]
[47]
[48]
[53]
[54]
[37]
[40]
[45]
[51]
[57]
[61]
[60]
[46]
[52]
[59]
[39]
[44]
[50]
[56]
[67]

Table of Contents