Engineer programming via the browser
17
Configuration
227
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Restriction
System Option
Description
two activations may come from the same device if
the activations differ in type, i.e. alarm / tamper.
- 1 Alarm activation followed by an ATS[1] Fault
within 30 minutes (default).
- ATS fault followed by a tamper or alarm condition
within 30 minutes (default).
If the 30 minutes expires and the zone is restored to
its normal physical state, then the zone’s alerts will
be restored if a level 2 user can restore this alert. In
this case, the zone will accept a new alert condition
which will cause a new activation.
Alternatively, if the zone has not been restored to its
normal physical state then that zone will be inhibited
if that zone is allowed to be inhibited.
If an alert (ATS) reoccurs after the 30 minute window
(default), then the 30 minute timer will restart.
The EN50131-9 confirmation option is automatically
set whenever the Standards -> Region option is set
to Spain.
VDS
This will enforce compliance with the VDS standard.
Keypad
Always Show
State
(SHOW STATE)
If enabled, the setting status of the system (Fullset /
Partset / Unset) is permanently displayed in the bottom
line of the keypad display. If unchecked the setting status
will disappear from the keypad display after 7 seconds.
Show Open
Zones
If enabled, open zones will display on keypad in Unset
mode.
Call ARC
Message
If enabled, the ARC message will be displayed for 30
seconds after Unset, if confirmed alarm has been
reported..
Call ARC Line 1
ARC message in line 1 of display (16 chars).
Call ARC Line 2
ARC message in line 2 of display (16 chars).
Show Cameras
If enabled, offline cameras will be displayed on the
keypad in Unset mode.
Idle State
Language
Select the language displayed in idle state.
System Language: Language in which menus and
texts on the keypads, the web interface and the event
log will be displayed.
Last Used: Last used language is displayed in idle
state.
PIN
PIN Digits
Enter the number of digits for user PINs (max. 8 digits).
Increasing the number of digits will add the relevant
number of zeros to the front of an existing PIN, e.g. an
existing user PIN of 2134 (4 digits) will change to
00002134 if the PIN digits is set to 8. If you decrease the
number of PIN digits, existing PINs will have their leading
digits removed, e.g. an existing user PIN of 00002134 (8
digits) will change to 02134 if the PIN digits is set to 5.
Note: This option cannot be changed if an SPC Manager
PIN digit mode is set. Refer to page [➙ 303]
Note: To comply with INCERT approvals, the user’s PIN
code must contain more than 4 digits.
!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals