17
Engineer programming via the browser
Configuration
240
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Configure the operation of particular zones for both Partset A and Partset B modes
as detailed below:
Partset Enable
Enable PartSet for A and B operation as required.
Partset Timed:
Tick the relevant checkbox (Partset A or B) to apply the exit
timer to the Partset A or B mode.
Partset Access:
Tick the relevant checkbox to change access zones into
entry/exit type zones for either Partset A or B operation. This
feature is useful for a domestic installation where a Passive
Infrared (PIR) sensor is located in the hallway. If the user
partsets the system at night and returns downstairs during the
night, he/she may unintentionally activate the PIR sensor in
the hallway and trigger the alarm. By setting the partset
access option, the buzzer will sound for the entry time period
when the PIR sensor is activated thereby warning the user
that the alarm will activate if no action is taken.
Partset Exit/Entry:
Tick the relevant checkbox to change the behaviour of
entry/exit zones to alarm zones when in Partset A or B mode.
This feature is useful for a domestic installation when the
system has been set in partset mode. If the user partsets the
system at night he/she may wish the alarm to activate
immediately if the front or back door is opened during the
night.
Partset Local:
Tick the relevant checkbox to restrict the reporting of alarms
in Partset Mode to local reporting only (No remote reporting).
No Bells
If ticked, no bells will be activated for partset A or B.
Linked Areas
This section enables you to link areas for setting and unsetting purposes:
Fullset
Fullset this area when all linked areas are Fullset.
Fullset All
Fullset all areas when this area is Fullset.
Prevent Fullset
Prevent this area from Fullset if all linked areas are Fullset.
Prevent Fullset All
Prevent linked areas from Fullset if this area is not Fullset.
Unset
Unset this area when all linked areas are Unset.
Unset All
Unset all areas when this area is Unset.
Prevent Unset
Prevent this area from Unset if any linked areas are Fullset.
Prevent Unset All
Prevent linked areas from Unset if this area is Fullset.
Authorise Setting
Enable authorised setting for linked areas. Refer
Authorised Setting of the Blocking Lock.
Linked Areas
Click on the areas that you wish to link to this area.
Schedule
Configure scheduling with the following settings:
Calendar
Select a calendar to control scheduling.
Unset
Select if area should automatically Unset as
per the time specified in the selected
calendar.
Fullset
Select this option to Fullset the area as per
17.9.5.2.3
17.9.5.2.4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals