Engineer programming via the browser
17
Configuration
241
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
the time specified in the selected Calendar.
The area will also set when the Unset
Duration or Delay Interval has elapsed (See
Setting and Unsetting [âž™ 243] section). If
the Unset Duration overlaps the scheduled
time, the area will use the calendar settings.
Time Locked
Select this option to time lock the area as
per the selected Calendar. (Vault type area
in Financial mode only)
Vault Access
Enter the number of minutes (0 – 120) to
activate this timer at the end of a Time
Locked Unset period. If the area is not unset
after this timer expires, the area cannot be
unset until the start of the next Time Locked
Unset period. (Vault type area in Financial
mode only)
Reporting
The Reporting configuration settings are applicable for Standard Areas in
Commercial and Financial installations only and are only relevant if a calendar
has been selected. (See Schedule [âž™ 240] section)
These settings enable a report to be sent to the Control Centre or nominated
personnel if the panel is Set or Unset outside scheduled calendar times.
Early to Set
Enables a report to be sent if the panel is manually Fullset before a
scheduled Set and before the number of minutes entered in the
Timer field.
Late to Set
Enables a report to be sent if the panel is manually Fullset after a
scheduled Set and after the number of minutes entered in the Timer
field.
Early to Unset
Enables a report to be sent if the panel is manually Unset before a
scheduled Unset and before the number of minutes entered in the
Timer field.
Late to Unset
Enables a report to be sent if the panel is manually Unset before a
scheduled Unset and before the number of minutes entered in the
Timer field.
Reporting is done via SMS or to the ARC via SIA and Contact ID. An event is also
stored in the system log.
Only events configured for late or early reporting for the area will be reported.
Event reporting must also be enabled for an ARC or SMS, as described in the
following sections.
Enabling Reporting of Unusual Setting/Unsetting for an ARC
To configure event reporting for an ARC configured to communicate over SIA or
CID, select Communications>Reporting>Analog ARC> Edit>Filter to display the
Event Filter page for an ARC.
17.9.5.2.5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals