17
Engineer programming via the browser
Configuration
248
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Attribute
Description
Unset inside (Browser)
Unset on Exit Reader (SPCPro)
Panel/area will unset, when card is presented at exit
reader.
Bypass alarm
Access is granted if an area is set and the door is an
alarm or an entry zone type.
Fullset outside (Browser)
Fullset on Entry Reader (SPCPro)
Panel/area will fullest, when card is presented twice
at entry reader.
Fullset inside
Full set on Exit Reader (SPCPro)
Panel/area will fullest, when card is presented twice
at exit reader.
Force Fullset
If the user has rights, they can force set from entry
reader.
Emergency
Door lock opens if a fire alarm is detected within the
assigned area.
Emergency any
Fire in any area will unlock the door.
Escort
The escort feature enforces privileged card holders to
escort other card holders through specific doors. If
this feature is assigned to a door, a card with the
“escort right” has to be presented first, to allow other
cardholders without this right to open the door. The
time period in which cardholders are able to present
their cards after a card with escort right was
presented, can be configured per door.
Prevent Passback*
Anti-passback should be enforced on the door. All
doors must have entry and exit readers and must be
assigned to a door group.
In this mode, cardholders must use their access card
to gain entry into and exit from a defined door group.
If a valid cardholder has presented his access card to
enter a door group and not presented the card to exit
it, the cardholder is in breach of the Anti-Passback
rules. Next time the cardholder attempts to enter the
same door group, a hard Anti-Passback alarm will be
raised and the cardholder will not be permitted entry
to the door group.
Soft Passback*
Anti-passback violations are only logged. All doors
must have entry and exit readers and must be
assigned to a door group.
In this mode, cardholders must use their access card
to gain entry to and exit from a defined door group. If
a valid cardholder has presented his access card to
enter a door group and not presented the card to exit
it, the cardholder is in breach of the Anti-Passback
rules. Next time the cardholder attempts to enter the
same door group, a Soft Anti-Passback alarm will be
raised. However, the cardholder will still be permitted
entry to the door group.
Custodian*
The custodian feature allows a card holder with
custodian right (the custodian) to give other
cardholders (non-custodians) access to the room.
The custodian must be the first to enter the room. The
non-custodians are only allowed to enter if the
custodian is in the room. The custodian will not be
allowed to exit until all non-custodians have left the
room.
Door Sounder
Door controller PCB mounted sounder sounds on
door alarms.
Ignore Forced
Door forced open is not processed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals