Engineer programming via the browser
17
Configuration
249
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Attribute
Description
Interlock* (Browser)
Limit Interlocked Door Access
(SPCPro)
Only one door in an area will be allowed open at a
time. Requires Door Group.
Setting Prefix
Authorisation with prefix (A,B,* or #) key to set system
* Require door group
Door timers
Timer
Min.
Max.
Description
Access granted
1 s
255 s
The time the lock will remain open
after granting access.
Access deny
1 s
255 s
The duration after which the
controller will be ready to read the
next event after a invalid event.
Door open
1 s
255 s
Duration within which the door
must be closed to prevent a “door
open too long” alarm.
Door left open
1 min
180 min
Duration within which the door
must be closed to prevent a “door
left open” alarm.
Extended
1 s
255 s
Additional time after granting
access to a card with extended
time attribute.
Escort
1 s
30 s
Time period after presenting a card
with escort attribute within a user
without escort right can access the
door.
Door calendar
Door locked
Select a calendar which should lock the door during the configured
time. No card / pin will be accepted during this time.
Door locked
Select a calendar which should unlock the door. The door will be
unlocked during the configured time.
Door triggers
Trigger
Description
Triggers that will Momentarily Unlock door
If the assigned trigger is activated, the door will
unlock for a defined period, then lock again.
Trigger that will lock the door
If the assigned trigger is activated, the door will
get locked. No card / PIN will be accepted.
Trigger that will unlock the door
If the assigned trigger is activated, the door will
get unlocked. No card / PIN will be needed to
open the door.
Trigger that will set the door to normal
If the assigned trigger is activated, the door will
get back to normal operation. This is to undo
locking / unlocking of the door. A card / will be is
needed to open the door.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals