11.10 H: Terminal Functions
538 YASKAWA SIEPC71061705H GA700 Series Technical Manual
Setting Value Function Description Ref.
113 !Speed Agree 2
The terminal deactivates when the output frequency is in the range of the frequency reference ± L4-04 [Speed
Agree Detection Width(+/-)].
Note:
The drive uses the motor speed as the reference in CLV and CLV/PM.
ON : The output frequency is not in the range of “frequency reference ± L4-04”.
OFF : The output frequency is in the range of “frequency reference ± L4-04”.
844
114 !User-Set Speed Agree 2
The terminal deactivates when the output frequency is in the range of L4-03 [Speed Agree Detection Level(+/-)] ±
L4-04 [Speed Agree Detection Width(+/-)] and in the range of the frequency reference ± L4-04.
ON : The output frequency is not in the range of “L4-03 ± L4-04” nor the range of frequency reference ± L4-04.
OFF : The output frequency is in the range of “L4-03 ± L4-04” and the range of frequency reference ± L4-04.
844
115 !Frequency Detection 3
The terminal activates when the output frequency is higher than “L4-03 [Speed Agree Detection Level(+/-)] + L4-
04 [Speed Agree Detection Width(+/-)]”. When the terminal activates, it stays activated until the output frequency
= L4-03.
Note:
• The detection level set in L4-03 is a signed value. Detections only occur one specific orientation.
• The drive uses the motor speed as the reference in CLV and CLV/PM.
ON : The output frequency is higher than L4-03 + L4-04.
OFF : The output frequency is less than L4-03 or is not more than L4-03 + L4-04.
844
116 !Frequency Detection 4
The terminal deactivates when the output frequency is higher than the value of L4-03 [Speed Agree Detection
Level(+/-)]. After the terminal deactivates, the terminal stays deactivated until the output frequency = L4-03 - L4-
04.
ON : The output frequency is less than “L4-03 - L4-04,” or it is not more than L4-03.
OFF : The output frequency is more than L4-03.
844
117 Torque Detection 1 (N.
O.)
The terminal activates when the drive detects overtorque or undertorque.
ON : The output current/torque exceeds the torque value set with L6-02 [Torque Detection Level 1], or the level
has dropped and remained in this state longer than the time set with L6-03 [Torque Detection Time 1].
844
118 Torque Detection 2 (N.
C.)
The terminal deactivates when the drive detects overtorque or undertorque.
OFF : The output current/torque exceeds the torque value set with L6-05 [Torque Detection Level 2], or the level
has dropped and remained in this state longer than the time set with L6-06 [Torque Detection Time 2].
844
119 Torque Detection 2 (N.
O.)
The terminal activates when the drive detects overtorque or undertorque.
ON : The output current/torque exceeds the torque value set with L6-05 [Torque Detection Level 2], or the level
has dropped and remained in this state longer than the time set with L6-06 [Torque Detection Time 2].
844
11A !During Reverse
The terminal deactivates when the motor operates in the reverse direction.
ON : The motor is operating in the forward direction or the motor stopped.
OFF : The motor is operating in the reverse direction.
844
11B During Baseblock (N.O.)
The terminal activates during baseblock. When the drive is in baseblock, the drive output transistor stops switching
and does not make DC bus voltage.
ON : During baseblock
OFF : The drive is not in baseblock.
844
11C !Motor 2 Selected
The terminal deactivates when motor 2 is selected.
ON : Motor 1 Selection
OFF : Motor 2 Selection
844
11D !During Regeneration
The terminal deactivates when the motor is regenerating.
ON : Motor is operating or stopped.
OFF : Motor is regenerating.
844
11E !Executing Auto-Restart
The terminal deactivates when the Auto Restart function is trying to restart after a fault.
844
11F !Motor Overload Alarm
(oL1)
The terminal deactivates when the electronic thermal protection value of the motor overload protective function is
a minimum of 90% of the detection level.
844
120 !Drive Overheat Pre-
Alarm (oH)
The terminal deactivates when the drive heatsink temperature is at the level set with L8-02 [Overheat Alarm
Level].
844
121 !Safe Torque OFF
The terminal deactivates (safety stop state) when the safety circuit and safety diagnosis circuit are operating
correctly and when terminals H1-HC and H2-HC are OFF (Open).
ON : Safety circuit fault or RUN/READY
OFF : Safety stop state
844