11.21 Defaults by Drive Model and Duty Rating ND/HD
618 YASKAWA SIEPC71061705H GA700 Series Technical Manual
No.
*1
Name Unit Default
- Drive Model - 4675
C6-01
Normal / Heavy Duty
Selection
-
HD1 ND
0 1
o2-04 Drive Model (KVA) Selection Hex. AE
E2-11
(E4-11)
Motor Rated Power kW 315 355
E2-02
(E4-02)
Motor Rated Slip Hz 1.25 1
E2-03
(E4-03)
Motor No-Load Current A 130 130
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 0.014 0.012
E2-06
(E4-06)
Motor Leakage Inductance % 20 20
E2-10
(E4-10)
Motor Iron Loss W 4700 5560
E5-01 PM Motor Code Selection - FFFF FFFF
L2-02 Power Loss Ride Through Time s 2 2
L2-03 Minimum Baseblock Time s 2.1 2.3
L2-04
Powerloss V/f Recovery Ramp
Time
s 2 2.2
L2-05
Undervoltage Detection Lvl
(Uv1)
- 380 380
L3-24
Motor Accel Time @ Rated
Torque
s 1.392 1.667
L8-02 Overheat Alarm Level °C 133 133
L8-09 Output Ground Fault Detection - 1 1
L8-38 Carrier Frequency Reduction - 2 2
n1-01 Hunting Prevention Selection - 2 2
n1-03
Hunting Prevention Time
Constant
ms 100 100
n1-16 Hunting Prevention High Fc Gain - 0.50 0.50
n5-02 Motor Inertia Acceleration Time s 1.392 1.667
*1 Parameters within parentheses are for motor 2.