12.8 H: Terminal Functions
800 YASKAWA SIEPC71061705H GA700 Series Technical Manual
Setting Value Function Reference
63 Field Weakening
816
65
*1
KEB Ride-Thru 1 Activate (N.C.)
816
66
*1
KEB Ride-Thru 1 Activate (N.O.)
817
67 Communications Test Mode
817
68 High Slip Braking (HSB) Activate
817
6A Drive Enable
817
71 Torque Control
817
72 Zero Servo
818
75 Up 2 Command
818
76 Down 2 Command
819
77 ASR Gain (C5-03) Select
819
78 Analog TorqueRef Polarity Invert
819
Setting Value Function Reference
7A
*1
KEB Ride-Thru 2 Activate (N.C.)
820
7B
*1
KEB Ride-Thru 2 Activate (N.O.)
820
7C
*1
Short Circuit Braking (N.O.)
820
7D
*1
Short Circuit Braking (N.C.)
820
7E Reverse Rotation Identifier
820
7F PID Bi-Directional Enable
821
90 to 97
*1
DWEZ Digital Inputs 1 to 8
821
9F DWEZ Disable
821
101 to 19F Inverse Inputs of 1 to 9F
Sets the function of the selected MFDI to operate
inversely. To select the function for inverse input,
enter two digits 01 to 9F for the “xx” in ”1xx”.
821
*1 Inverse input is not available.
■ H1-01: Terminal S1 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-01
(0438)
Terminal S1 Function
Selection
Sets the function for MFDI terminal S1.
40
(1 - 1FF)
Note:
The default setting is F when you initialize the drive for 3-Wire Initialization [A1-03 = 3330].
■ H1-02: Terminal S2 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-02
(0439)
Terminal S2 Function
Selection
Sets the function for MFDI terminal S2.
41
(1 - 1FF)
Note:
The default setting is F when you initialize the drive for 3-Wire Initialization [A1-03 = 3330].
■ H1-03: Terminal S3 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-03
(0400)
Terminal S3 Function
Selection
Sets the function for MFDI terminal S3.
24
(0 - 1FF)
■ H1-04: Terminal S4 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-04
(0401)
Terminal S4 Function
Selection
Sets the function for MFDI terminal S4.
14
(0 - 1FF)
■ H1-05: Terminal S5 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-05
(0402)
Terminal S5 Function
Selection
Sets the function for MFDI terminal S5.
3
(0 - 1FF)
Note:
The default setting is 0 when the drive is initialized for 3-Wire Initialization [A1-03 = 3330].