Docu ment No. E ZZ024048<1>
Pr epared in October, 2021
8 / 19
Se t the Trigger
The procedure in this section shows how to set the trigger for data logging.
Note: This setting is displayed only when short-term data log is selected for the data log
type.
1. Push (Home) to show the HOME screen.
Note: When the drive is in HOME Mode, the screen shows [Home] in the upper right-
hand corner of the screen.
If the screen does not show [Home] for , push (Back), and then push
to show [Home].
2. Push (Menu).
3. Push or to select [Diagnostic Tools], then push .
4. Push or to select [Data Logger], then push (Setup).
5. Push or to select [Log Trigger], then push .
6. Push or to select [Trigger Type Selection], then push .
7. Push or to select the type of trigger, then push .
Note: There are no detection width and detection time settings for the analog trigger in the
data log function. If variations in the analog signal become a problem, select the digital
trigger and use
o5-16 = 66/67 [Digital Trigger Object = Comparator 1/2].
Set the
conditions for the comparator function with
H2-20
to
H2-32
.

Table of Contents