Selects the monitor (
Ux-xx
) to set for the analog trigger
target. This parameter is only available when using an
L CD keypad.
0.0%
( - 999.9% -
+999.9%)
Sets the level to compare with the analog trigger target.
Thi s parameter is only available when using an LCD
keypad.
Selects the condition with which to detect the trigger.
Thi s parameter is only available when using an LCD
keypad.
0: Rising Edge
1: Falling Edge
Sets the percentage of data to save before the trigger
is detected for the short-term data log. This parameter
is only available when using an LCD keypad.
Trend Log
Samp ling Time
Selection
Selects the sampling cycle for the trend log to save data
b e fore the trigger is detected. The trend log works
con currently with the short-term data log. This
p arameter is only available when using an LCD keypad.
0: Trend Log Disabled
1: 0.1 s (About 1 hour)
2: 1 s ( About 10 hours)
3: 10 s ( About 100 hours)
4: 60 s ( About 600 hours)