InteliDrive DCU Marine - 3.0.0 Global Guide
95
Note: ESC is Engine Specific Code, it contains all necessary information about transmitted values, commands
and diagnostic messages.
Controller address – user adjustable number from 0 to 255, which defines address used by controller for
communication with the module. Controller can use different address for communication with different
modules. Default option is Default (X), X stands for actual address value, which comes from ESC and is
used by controller interface for communication with module, when the default option is used. N/A is
displayed as Controller address, if Modbus is used for communication with a module.
Note: Do not confuse Controller address with Comms settings: Contr.address, which is different parameter
with independent functionality.
Note: ESC is Engine Specific Code, it contains all necessary information about transmitted values, commands
and diagnostic messages.
Protection upon module failure – use it to select type of alarm, which is issued if communication with
module fails
Add screens – use it to display/hide module related screens
Display data as – information how are analog values displayed
Analog inputs – Number of analog input values available with module.
Note: Total number of available analog input values is limited to 160 with all configured modules (e.g. 4
modules with 40 inputs would use all available inputs).
Analog outputs– Number of analog output values available with module.
Note: Total number of available analog output values is limited to 40 with all configured modules (e.g. 5
modules with 8 outputs would use all available outputs).
Binary inputs – Number of binary input values available with module.
Note: Total number of available binary input values is limited to 160 with all configured modules (e.g. 4 modules
with 40 inputs would use all available inputs).
Binary outputs – Number of binary output values available with module.
Note: Total number of available binary output values is limited to 160 with all configured modules (e.g. 4
modules with 40 outputs would use all available outputs).
Analog inputs (4B) – Number of 4B analog input values available with module.
Note: Total number of available 4B analog input values is limited to 20 with all configured modules (e.g. 5
modules with 4 inputs would use all available inputs).
6 back to Controller setup