InteliDrive DCU Marine - 3.0.0 Global Guide
95
Note: ESC is Engine Specific Code, it contains all necessary information about transmitted values, commands
and diagnostic messages.
Controller address user adjustable number from 0 to 255, which defines address used by controller for
communication with the module. Controller can use different address for communication with different
modules. Default option is Default (X), X stands for actual address value, which comes from ESC and is
used by controller interface for communication with module, when the default option is used. N/A is
displayed as Controller address, if Modbus is used for communication with a module.
Note: Do not confuse Controller address with Comms settings: Contr.address, which is different parameter
with independent functionality.
Note: ESC is Engine Specific Code, it contains all necessary information about transmitted values, commands
and diagnostic messages.
Protection upon module failure use it to select type of alarm, which is issued if communication with
module fails
Add screens use it to display/hide module related screens
Display data as information how are analog values displayed
Analog inputs Number of analog input values available with module.
Note: Total number of available analog input values is limited to 160 with all configured modules (e.g. 4
modules with 40 inputs would use all available inputs).
Analog outputs Number of analog output values available with module.
Note: Total number of available analog output values is limited to 40 with all configured modules (e.g. 5
modules with 8 outputs would use all available outputs).
Binary inputs Number of binary input values available with module.
Note: Total number of available binary input values is limited to 160 with all configured modules (e.g. 4 modules
with 40 inputs would use all available inputs).
Binary outputs Number of binary output values available with module.
Note: Total number of available binary output values is limited to 160 with all configured modules (e.g. 4
modules with 40 outputs would use all available outputs).
Analog inputs (4B) Number of 4B analog input values available with module.
Note: Total number of available 4B analog input values is limited to 20 with all configured modules (e.g. 5
modules with 4 inputs would use all available inputs).
6 back to Controller setup