136 Upgrade and Maintenance Manual
RX2520 M4
Hard disk drive (HDD) and solid state drive (SSD)
V CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array! Be sure to back up your data before deleting a RAID
array. For more information, see the "ServerView Suite RAID
Management" user guide.
7.3.6.2 Removing a 2.5-inch HDD/SSD module
Ê Pinch the green locking clip (1) and open the locking lever (2).
Ê Pull the HDD/SSD module out a few centimeters (3).
Ê Wait about 30 seconds to allow the HDD to spin down.
I This is not necessary when removing an SSD.
I This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê Pull the HDD/SSD module completely out of its bay.
7.3.6.3 Installing a 2.5-inch dummy module
V CAUTION!
If the removed HDD/SSD module is not replaced immediately, always
replace a dummy module into the unused HDD/SSD bay to comply with
applicable EMC regulations and satisfy cooling requirements.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2520 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2520 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX2520 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2520 M4
CategoryServer
LanguageEnglish

Related product manuals