136 Upgrade and Maintenance Manual
RX2520 M4
Hard disk drive (HDD) and solid state drive (SSD)
V CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array! Be sure to back up your data before deleting a RAID
array. For more information, see the "ServerView Suite RAID
Management" user guide.
7.3.6.2 Removing a 2.5-inch HDD/SSD module
Ê Pinch the green locking clip (1) and open the locking lever (2).
Ê Pull the HDD/SSD module out a few centimeters (3).
Ê Wait about 30 seconds to allow the HDD to spin down.
I This is not necessary when removing an SSD.
I This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê Pull the HDD/SSD module completely out of its bay.
7.3.6.3 Installing a 2.5-inch dummy module
V CAUTION!
If the removed HDD/SSD module is not replaced immediately, always
replace a dummy module into the unused HDD/SSD bay to comply with
applicable EMC regulations and satisfy cooling requirements.