RX2520 M4
Upgrade and Maintenance Manual 251
Processor (CPU)
11.2 Upgrading to 2 CPUs configuration
V CAUTION!
– CPUs are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a
CPU has been removed from its protective sleeve or from its socket,
place it with its smooth side down on a non-conducting, antistatic
surface. Never push a CPU over a surface.
– Only CPUs of the same type may be used on the system board. That
means the number of the internal CPU cores as well as the primary
clock and the QPI frequency have to be the same.
– For dual operation, use a suitable multiprocessor operating system.
11.2.1 Preliminary steps
Ê "Suspending BitLocker functionality" on page 67
Ê "Shutting down the server" on page 48
Ê "Disconnecting the power cord" on page 49
Ê "Getting access to the component" on page 50
Ê "Removing the air duct" on page 61
Upgrade and Repair Unit
(URU)
Hardware: 15 minutes
Software: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2520 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2520 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX2520 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2520 M4
CategoryServer
LanguageEnglish

Related product manuals