RX2520 M4
Upgrade and Maintenance Manual 99
6 Power supply unit (PSU)
Safety notes
V CAUTION!
Do not disassemble the PSU. Doing so may cause electric shock.
Areas around the PSU may remain extremely hot after shutdown.
After shutting down the server, wait for hot components to cool down
before removing the PSU.
When installing a PSU, ensure that the connector of the PSU is not
damaged or bent.
The PSU is heavy, so handle it carefully. If you drop it by mistake,
injuries may result.
For more information, see chapter "Important information" on
page 33.
6.1 Basic information
AC PSU
The server can be equipped with up to two AC PSUs.
In its basic configuration, the server has one PSU that adjusts automatically to
any mains voltage in the range of 100 VAC to 240 VAC. Besides the PSU, a
second PSU can be installed optionally to serve as a redundant power supply.
If one PSU fails, the second PSU in the redundant configuration ensures
operation can continue uninterrupted and the defective PSU can be replaced
during operation (hot-plug).
I For 800 W Titanium PSU:
Mains input voltage range: 200 V – 240 V
V CAUTION!
The server supports a mains voltage in the range of 100 VAC to
240 VAC. You may only operate the server if its rated voltage range
corresponds to the local mains voltage.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2520 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2520 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX2520 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2520 M4
CategoryServer
LanguageEnglish

Related product manuals