RX2520 M4
Upgrade and Maintenance Manual 91
Basic software procedures
Figure 17: Progress bar (RAID array rebuild)
V CAUTION!
The system is now operational, however, data redundancy will not be
available until the RAID array rebuild is complete. Depending on the
HDD capacity the overall process can take up to several hours, in some
cases even days.
I You may notice a slight performance impact during rebuild.
5.2.16 Looking up changed MAC/WWN addresses
When replacing a network controller, the MAC (Media Access Control) and
WWN (World Wide Name) addresses will change.
I In addition to the procedures described below, MAC/WWN addresses
can also be found on the type label attached to a network controller or
system board.
5.2.16.1 Looking up MAC addresses
Ê Log in to the ServerView iRMC web interface.
Ê Open the Settings menu.
Ê Open the Baseboard Management Controlller page.
Ê In the Network Interface group, you will find more information on each
network controller in the managed PRIMERGY server, including its MAC
address.