Basic software procedures
Ê Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific CPU:
Ê Log in as root.
Ê Enter the command below, followed by [ENTER]:
– For rack and floorstand servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
– For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204
I <CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
Ê If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all CPUs:
Ê Log in as root.
Ê Enter the commands below, followed by [ENTER]:
1. /etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2. cd /etc/srvmagt
3. rm -f cehist.bin
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
Ê Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2520 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2520 M4 and is the answer not in the manual?

Fujitsu PRIMERGY RX2520 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2520 M4
CategoryServer
LanguageEnglish

Related product manuals