TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 149
Basic software procedures
Ê Enter BIOS recovery mode using the onboard jumpers.
I For detailed information on jumper settings, refer to section "Onboard
settings" on page 950.
Ê Close the side / top cover as described in section "Closing the server" on
page 112.
Ê Connect the USB stick to the USB port.
Ê Connect the server to the mains as described in section "Connecting the
server to the mains" on page 133.
Ê Press the On / Off button to start up the server.
The system will detect the USB stick and the BIOS recovery process will be
performed.
V CAUTION!
Do not interrupt the BIOS recovery process after it has started. If the
process is interrupted, the system BIOS may be permanently
corrupted.
Ê After completion of the flash process, shut down the server.
Ê Open the side / top cover as described in section "Opening the server" on
page 79.
Ê Disable BIOS recovery mode using the onboard jumpers:
I For detailed information on jumper settings, refer to section "Onboard
settings" on page 950.
Ê Close the side / top cover as described in section "Closing the server" on
page 112.