TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 391
Fans
Figure 246: Mounting the system fan holder (B)
Ê Carefully lower the fan holder into the chassis (1) until the two locking tabs
(2, see close-ups) engage.
Ê Ensure that the connectors on the fan modules properly engage with the fan
connectors on the system board.
8.2.2.5 Concluding steps
Perform the following procedures to complete the task:
Ê Reinstall the air duct as described in section "Installing the system air duct"
on page 102.
Ê Close the side / top cover as described in section "Mounting the top cover"
on page 115 (rack server) or "Mounting the side cover" on page 122 (tower
server).
Ê When working on a rack-mounted server, secure it in the rack as described
in section "Sliding the server into the rack" on page 132.
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 130.