TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 593
Main memory
Ê When working on a rack-mounted server, extend it out of the rack as
described in section "Extending the server out of the rack" on page 76.
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page 77.
Ê Bring the server to its horizontal position.
Ê Open the side / top cover as described in section "Removing the top cover"
on page 79 (rack server) or "Removing the side cover" on page 88 (tower
server).
Ê Remove the air duct as described in section "Removing the system air duct"
on page 100.
10.2.3 Installing a memory module
Ê Identify the correct memory slot according to the mounting order described
in section "Memory sequence" on page 584.
Figure 404: Installing memory modules (A)
Ê Press out the securing clip at each end of the memory module connector.
I For lack of space, it is necessary to remove the left rear fan (fan 5) in
order to install or remove memory modules in channels E and F. For
further information, please refer to section "Removing a rear fan
module" on page 397.