746 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Accessible drives
12.7.1.4 Removing accessible drive dummy covers
Removing accessible drive filler covers
Ê Remove accessible drive filler covers from installation bays 1, 2 and 3 as
described in section "Removing accessible drive filler covers" on page 656.
V CAUTION!
Always replace filler covers into unused drive bays to comply with
applicable EMC regulations and satisfy cooling requirements.
Removing accessible drive covers
Ê Remove accessible drive covers from installation bays 1, 2 and 3 as
described in section "Removing accessible drive covers" on page 657.
12.7.1.5 Installing the 4x 3.5-inch HDD extension box
Ê Prepare the accessible drive mounting brackets and install the 4x 3.5-inch
HDD extension box into installation bays 1, 2 and 3 as described in section
"Installing the 4x 3.5-inch HDD extension box" on page 334.
12.7.1.6 Cabling the slimline ODD on the HDD extension box
I For SAS cabling of HDD extension box backplanes, please refer to
section "HDD extension boxes" on page 309.
The cabling list number and cabling plan sections in the allocation tables
below refer to chapter "Cabling" on page 909.
Ê Connect the SATA and power cables as shown in the tables above.
Cable
(T26139-)
Cabling
list no.
from to
Cabling
plan
SATA cable
Y3958-V205
20 Slimline ODD
System board
connector SATA 1
16.2.1
Slimline ODD SATA
power cable
Y3986-V302
8A / 8B
Slimline ODD
(15-pin SATA)
3.5-inch HDD
backplane 2
connector X9
(4-pin connector)
16.2.7
16.2.4