TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 601
Main memory
10.4.5 Concluding steps
Perform the following procedures to complete the task:
Ê Reinstall the air duct as described in section "Installing the system air duct"
on page 102.
Ê Close the side / top cover as described in section "Mounting the top cover"
on page 115 (rack server) or "Mounting the side cover" on page 122 (tower
server).
Ê When working on a rack-mounted server, secure it in the rack as described
in section "Sliding the server into the rack" on page 132.
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 130.
Ê Reconnect the AC power cords to the power supply units and secure them
with PSU cable brackets as described in section "Connecting the server to
the mains" on page 133.
Ê If available, update the system board BIOS to the latest version as described
in section "Updating or recovering the system board BIOS and iRMC" on
page 147.
Ê Enable boot watchdog functionality as described in section "Enabling SVOM
boot watchdog functionality" on page 159.
Ê Enable the replaced memory module(s) as described in section "Enabling
replaced components in the system BIOS" on page 160.
Ê Verify if the memory mode has been restored to its original state as
described in section "Verifying the memory mode" on page 160.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 165.