EasyManua.ls Logo

Fujitsu PRIMERGY TX300 S7 - Removing 3.5-Inch HDD Modules; Required Tools; Preliminary Steps

Fujitsu PRIMERGY TX300 S7
962 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX300 S7 / RX350 S7 Upgrade and Maintenance Manual 277
Hard disk drives / solid state drives
7.3.7 Removing 3.5-inch HDD modules
7.3.7.1 Required tools
Preliminary and concluding steps: tool-less
Removing a 3.5-inch HDD module: tool-less
7.3.7.2 Preliminary steps
Before removing a 3.5-inch HDD module, perform the following steps:
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0
array if defective.
V CAUTION!
Removing an operational HDD module will
result in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 166.

Table of Contents

Other manuals for Fujitsu PRIMERGY TX300 S7

Related product manuals