256 Upgrade and Maintenance Manual TX300 S7 / RX350 S7
Hard disk drives / solid state drives
Figure 138: Securing the 16x 2.5-inch HDD front panel
Ê Firmly press down on the HDD front panel until its upper edge is flush with
the chassis (see arrow).
Ê Secure the HDD front panel to the server front with four M3 x 4.5 mm screws
(see circles).
7.2.9.8 Cabling the SAS backplanes
Ê Connect SAS and power cables to the 2.5-inch SAS backplanes as
described in section "8x 2.5-inch HDD SAS backplane cabling" on page 201.
7.2.9.9 Concluding steps
Perform the following procedures to complete the task:
Ê Reinstall the system fan holder as described in section "Installing the system
fan holder" on page 390.
Ê Reinstall the air duct as described in section "Installing the system air duct"
on page 102.
Ê Close the front cover and reinstall the ID card as described in section
"Closing the server" on page 112.